2.2.1 C-Series Network Connection Topologies
The CN series OCS can be interfaced to legacy serial POS systems or fully network enables POS systems using
standard CAT5 cabling.
2.2.1.1 Legacy POS Ethernet Solution
For legacy POS systems that only support a serial interface to the OCS, a Serial Server is used to convert the serial
output to Ethernet as shown below. This topology allows the use of the in-store network for both the transmission of
POS transaction data and content updates to the OCS.
C-Series OCS
Standard network Hub
Back Office PC
CAT5
DTOT POS Terminal
w/ Serial Output
CAT5
WAN /
Internet /
Dial Up
Serial Server
RS-232
CAT5
Figure 5 – Legacy POS Ethernet System Configuration Diagram
2.2.1.2 Total Ethernet Solution
For POS systems that support a network interface to the OCS, the Total Ethernet Solution topology shown below is
recommended. This is the lowest cost and most reliable configuration, utilizing standard network hardware and
CAT5 cabling.
C-Series OCS
Standard Network Hub
Back Office PC
CAT5
Networked POS Terminal
CAT5
WAN /
Internet /
Dial Up
CAT5
Figure 6 – Total Ethernet System Configuration Diagram